FAIZEAL · CUSTOM MAGNETIC COMPONENTS · OEM AND ODM
Two pieces of physics, one bonded block. A customer-specific linear Halbach array built from insulated NdFeB laminations — concentrating flux on the working face, self-shielding the back, and suppressing the eddy currents that would otherwise heat the magnet itself at high electrical frequency.
Nine-segment linear Halbach array · Sintered NdFeB in the N45SH temperature grade · Black and grey epoxy segment encoding · Insulated laminations bonded with Loctite 326 and activator 7448 · Sliced, magnetised, bonded and verified in-house by FAIZEAL
This is a customer-specific magnet assembly, not a catalogue item. It was developed from a released assembly drawing for a linear magnetic circuit in which the working side had to be strong, the back side had to be quiet, and the magnet had to survive a high-frequency alternating field without heating itself.
The photograph shows the finished block. It is a rectangular prism whose long face carries nine alternating bands, five black and four light grey, each band separated by a clean joint line. Those bands are not a printed pattern and not a decorative finish. They are nine individual magnet segments, and the two colours identify two different roles in the Halbach sequence.
The assembly drawing confirms the detail. The block is built from five type A segments in black epoxy and four type B segments in grey epoxy, alternated so that type A appears at both ends. The magnet material is sintered NdFeB in the N45SH temperature grade, and the segments are bonded with Loctite 326 structural adhesive used with activator 7448.
In the drawing the red and blue bands encode magnetisation direction rather than colour: some segments are shown in a single colour for a field normal to the working face, and others are split across their height for a field rotated into the plane of the array. The fine vertical lines in the plan view are the lamination boundaries inside each segment. The isometric view shows how those slices and segments come together in the finished block.
Delivered assembly | Specification on the drawing |
Overall dimensions | 97 ± 0.3 mm along the array, with 43 ± 0.3 mm and 22 ± 0.3 mm on the two transverse dimensions |
Magnet material | Sintered NdFeB, N45SH temperature grade, rated for continuous operation around 150 °C |
Segment build | Nine laminated segments, five type A and four type B, alternating with type A at both ends |
Surface finish | Black epoxy on type A segments, grey epoxy on type B segments, applied before assembly |
Magnetisation | Linear Halbach sequence with the working face reinforced and the back face self-shielding |
Segment bonding | Loctite 326 structural adhesive with activator 7448, room-temperature cure in a controlled fixture |
Assembly tolerance | ± 0.3 mm on the three principal dimensions, with tighter internal control on the laminations |
Halbach geometry and lamination solve two completely different problems. The Halbach sequence decides where the flux goes. Lamination decides whether the magnet survives the field it is sitting in. Neither one substitutes for the other, and this part needed both at once.
Consider a conventional alternating-pole array first. Its field is broadly symmetric: as much flux leaves the back of the magnet as the front, so a steel back-iron is needed to return it and push it towards the air gap. That back-iron adds mass, adds rotating inertia in a machine, and does nothing useful on the working side.
Now consider a solid sintered NdFeB magnet in a high-speed or high-frequency machine. Sintered NdFeB conducts electricity. The slotting harmonics, the inverter current harmonics and the fundamental electrical frequency at high speed all induce circulating eddy currents inside the magnet body. Those currents do no useful work. They generate heat, raise the magnet temperature and can drive a local region past its irreversible demagnetisation limit.
A Halbach array built from solid magnets therefore wins the field battle and loses the thermal one. A laminated block with ordinary pole orientation wins the thermal battle and still needs back-iron. Only the combination gives a strong, cool, lightweight working face with a quiet back.
What makes this combination genuinely difficult is that the three process requirements pull against each other. Lamination demands an unbroken insulating layer between every slice. Segment bonding demands a strong structural joint between every block. The Halbach sequence demands that each block carry a different magnetisation direction. A mistake in any one of the three is invisible on the finished part and shows up only as a disappointing field measurement.
In a Halbach array the magnetisation vector rotates from segment to segment in a defined sequence. Main pole segments are magnetised normal to the working face; transition segments are magnetised tangentially or obliquely. Where those vectors superimpose on the working side they add constructively, and on the back side they cancel.
The practical result is a one-sided, or self-shielding, field. Without adding any magnet volume, the air-gap flux density is typically 30 to 50 percent higher than a conventional radial or alternating arrangement of the same grade and size. Because the back field is largely cancelled, the steel back-iron can be reduced or removed entirely, which cuts mass and inertia in a moving assembly.
The quiet back face matters just as much as the strong front. Encoders, Hall sensors, bearings, cabling and nearby electronics sit behind a magnet track in most real machines. A self-shielding array keeps stray field away from them, which removes a whole class of interference and signal-integrity problems from the integration work.
The field distribution is also closer to sinusoidal than a conventional square-ish pole pattern. In a motor or a linear drive that translates into roughly 60 to 80 percent lower cogging torque, smoother low-speed motion and less acoustic noise — a decisive advantage in robot joints, precision stages and servo axes.
There is a trade-off in the number of segments per pole period. Three segments already give a field gain of about 1.5, four give about 1.7, and the theoretical limit approaches 2 as segmentation becomes continuous.
Real designs usually settle between three and six, because every extra segment adds another joint, another glue line and another chance for angular error. The nine segments on this block were fixed by the customer's pole pitch and space envelope, not chosen for maximum theoretical gain.
Sintered NdFeB has a resistivity of roughly 1.4 microohm metres, so it behaves as a conductor when the field through it changes. The alternating component at the magnet surface comes from stator and rotor slotting, from inverter-induced current harmonics, from the variable reluctance as poles pass salient teeth, and, most severely, from the fundamental electrical frequency at high mechanical speed.
The skin-depth relation sets the scale of the problem. At 1 kHz the penetration depth in NdFeB is around 0.6 mm; at 5 kHz it falls to about 0.27 mm and at 10 kHz to about 0.19 mm. A solid magnet five or ten millimetres thick cannot shed the heat generated in that thin surface skin, so the surface runs hot while the centre stays cool. Local overheating, not average temperature, is what causes partial irreversible demagnetisation.
Lamination slices the magnet into sheets thinner than the skin depth at the operating frequency and insulates every sheet from its neighbours. Eddy-current loss scales approximately with the cube of sheet thickness, so a 0.35 mm lamination produces on the order of a hundredth of the loss of a 5 mm solid block at the same frequency. Across a whole assembly the magnet eddy-current loss typically falls by 60 to 90 percent.
Less internal heating means a 30 to 50 percent lower magnet temperature rise, an efficiency gain of one to three percentage points at machine level, more margin against demagnetisation during overload or fault current, and the ability to run at higher speed without thermal derating. Machines in the tens of thousands of revolutions per minute are practical for exactly this reason.
The insulation layer is where laminated magnets succeed or fail. Epoxy at 10 to 25 micrometres is the common choice; ceramic at 5 to 10 micrometres suits high temperatures; polyimide at 15 to 30 micrometres suits high-reliability duty; parylene at 5 to 15 micrometres suits medical, vacuum and semiconductor work.
Coverage must include the edges. A single pinhole or an uncoated edge shorts two adjacent sheets together and creates a local eddy path that runs hot, so insulation resistance between sheets is checked on every assembly.
The delivered block is nine segments long. Five type A segments in black epoxy and four type B segments in grey epoxy alternate, with type A at both ends, so the finished face reads black, grey, black, grey, black, grey, black, grey, black from one end to the other. On a 97 mm array that puts each segment at roughly 10.8 mm, with the joint lines you can see in the photograph marking the boundaries.
Each of those segments is itself a laminated stack. The slices are cut from sintered NdFeB blank by wire electrical discharge machining or diamond sawing, insulated, then stacked and bonded in a fixture before being ground to final size. Only after that are the segments brought together into the full array. The structure is therefore laminated in one direction and segmented in the other.
The two orthographic views on the drawing reflect that. The front view shows the alternating red and blue bands and the rotated magnetisation of the transition segments. The plan view shows the fine parallel lines of the lamination slices running through the length of the block. The isometric view shows both at once: a striped working face, and segment ends and side faces in which the rotated magnetisation is visible.
The three principal dimensions are 97 ± 0.3 mm along the array with 43 ± 0.3 mm and 22 ± 0.3 mm across it. That ± 0.3 mm band is an assembly-level tolerance, set by how the block fits the customer's magnet track or carrier. It is deliberately looser than the tolerances held inside the stack, and that difference is intentional rather than careless.
The two epoxy colours are first and foremost a magnetisation-direction code and an assembly mistake-proofing measure. In a Halbach array, adjacent segments look identical but their magnetisation vectors differ by a right angle. Fit one segment rotated or reversed and the finished block looks perfectly normal — the one-sided field simply collapses and stray field reappears on the back.
Encoding type A and type B in two contrasting epoxies makes the sequence visible at every stage: to the operator stacking the segments, to the inspector checking the bond, and to the customer's goods-in team years later when a spare is fitted. The stripe pattern in the product photograph is that code, not a styling choice.
The coating earns its place functionally too. Black epoxy adds electrical insulation, gives surface insulation resistance above 100 megohms, carries a neutral salt-spray rating in the 500 to 1000 hour range, resists motor coolants and lubricants, and has a low-gloss finish that does not reflect into optical or semiconductor equipment. Grey epoxy gives type B segments the same protection while keeping the visual distinction.
Timing matters. The coating is applied to the individual slices or segments before stacking and assembly, so that edges are properly covered. Spraying a finished block afterwards would bridge the insulation between slices, fill the segment joints and change the very interfaces the design depends on.
There is a quieter benefit as well. Mixed batches, warranty returns and field repairs are much easier to manage when the two segment types cannot be confused by eye. For a part that is made to a single customer drawing, that traceability is worth as much as the corrosion resistance.
The drawing specifies Loctite 326 structural adhesive with activator 7448. That is an anaerobic system that cures at room temperature, which is the point: the assembly never has to be baked. A high-temperature cure would put the insulation layers and the magnet grade under thermal stress at the same time, and would add an oven cycle to every batch.
A room-temperature structural bond also gives a thin, repeatable glue line. Dispensing volume, bond-line thickness and holding pressure are controlled throughout, with the adhesive filling the joint completely but never squeezing onto the working face. A bead of cured adhesive on the working face would locally increase the air gap and produce exactly the once-per-pass field dip the design is trying to avoid.
Alternative joining methods are worse here. A metallic coating or a mechanical clamp crossing the segment boundary would conduct electricity between laminations and rebuild a closed eddy-current loop at the joint — undoing the lamination in the one place where the field changes fastest. Clamping also concentrates load into small areas of a brittle sintered material that is weak in tension.
High-temperature-curing two-component epoxy remains an option where the duty demands it, and ceramic-based adhesives are used for samarium-cobalt assemblies above 200 °C. But for this N45SH block, a thin room-temperature cured joint gives the right balance of strength, dimensional control and thermal safety.
Every batch is validated by shear or pull testing on companion samples, and bond-line thickness is recorded on the traveller. The adhesive is treated as a designed layer with a tolerance, not as a consumable that happens to be there.
A laminated Halbach block has to satisfy two sets of dimensions that have almost nothing to do with each other. The outside dimensions decide whether the part fits the customer's hardware. The internal dimensions decide whether the field is right. Confusing the two is a common and expensive mistake.
At assembly level the drawing calls out ± 0.3 mm on the three principal dimensions. That is a sensible interface tolerance: it absorbs the customer's carrier machining, thermal expansion across the operating range and any shimming on site. Grinding the whole block to ± 0.02 mm would cost more and deliver no magnetic benefit, because the carrier it mates with is not that accurate.
Inside the stack, control is much tighter. Individual laminations are held to about ± 0.02 mm in thickness, stack alignment to 0.02 to 0.05 mm total indicated runout, and finished surfaces to ± 0.02 mm by grinding, with flatness and parallelism in the 0.02 to 0.05 mm band. These are the dimensions that set air-gap uniformity and flux symmetry.
Accumulated error is the reason the internal tolerances cannot be relaxed. A 0.02 mm thickness variation on each sheet of a thirty-sheet stack becomes 0.6 mm of total height error if nothing corrects it. Precision slicing, a locating fixture and a final grinding pass close the loop; sorting sheets by hand does not.
Segment joints accumulate in the same way. Nine segment widths and eight glue lines together determine the overall 97 mm length, so segment width and bond-line thickness are toleranced as a single budget rather than independently. That is also why the adhesive is specified and controlled rather than applied by eye.
Sequence is fixed on the shop floor: slice, surface-treat and insulate, stack and bond, cure, grind to final size, then magnetise, then map the flux. Cutting a magnetised assembly would pull ferrous swarf onto the working face and risk local demagnetisation from cutting heat, so no machining is allowed after magnetisation.
A Halbach array cannot be magnetised with one uniform field, because every segment needs a different vector direction. Two routes are used. Thin laminations can be magnetised individually at the angle required by their position and then stacked, or a dedicated multi-pole magnetising head with locating fixtures and magnetic shielding can magnetise the assembled block zone by zone.
Halbach arrays with up to eight segments per pole period and patterns up to 48 poles are within routine capability.
Whichever route is chosen, the pulse field has to reach two to three times the intrinsic coercivity of the grade to saturate properly. An under-magnetised assembly looks entirely normal and measures weak, which is why flux verification is the backstop rather than an optional extra.
Verification covers both physics problems. Inter-lamination insulation resistance is checked on every assembly. Each segment's magnetisation direction and pole arc are scanned with a gaussmeter and flux mapper. The ratio of working-side to back-side flux density is measured to confirm the one-sided effect — it is also the fastest way to catch a single reversed segment.
Overall dimensions go to the coordinate measuring machine, and circumferential flux uniformity is held within about 3 percent.
Bond shear strength, coating thickness, salt-spray or media-resistance results and the flux map are filed against the batch. A replacement block ordered two years later is therefore built to the same drawing, the same magnetising tooling and the same inspection plan, not merely to the same part number.
The nine-segment block shown here is one point in a wide design space. FAIZEAL engineers lamination thickness, insulation chemistry, Halbach segmentation, bonding and verification as one coupled system, so a change in any one of them is checked against the others before a drawing is released.
Design variable | Options FAIZEAL engineers to your magnetic circuit |
Lamination thickness | 0.20, 0.25, 0.30, 0.35, 0.50, 0.70, 1.00 and 1.50 mm standard; custom thicknesses from 0.10 to 2.00 mm; sheet thickness held to about ± 0.02 mm |
Inter-layer insulation | Epoxy 10 to 25 μm, ceramic 5 to 10 μm, polyimide 15 to 30 μm, parylene 5 to 15 μm, with full edge coverage and 100 percent insulation-resistance inspection |
Magnet material | Sintered NdFeB from N35 to N52 across M, H, SH, UH, EH and AH temperature grades; SmCo 1:5 and 2:17 for high-temperature or radiation-tolerant duty |
Halbach geometry | Linear, ring, arc, disc, segmented and skewed configurations; up to eight segments per pole period; four to 48 poles; custom field profiles and skewed magnetisation |
Stack geometry | Rectangular blocks, arc segments, D and T shapes, trapezoidal axial-flux segments and fully custom profiles, ground to final size after bonding |
Surface protection | Ni-Cu-Ni triple plating 20 to 35 μm, zinc 5 to 15 μm, black or grey epoxy, Everlube, parylene; two-colour segment encoding available |
Bonding system | Anaerobic structural adhesive with activator, two-component high-temperature epoxy, ceramic adhesive for SmCo; controlled bond line and room-temperature or oven cure |
Tolerance and balance | ± 0.05 mm standard and ± 0.02 mm precision on finished dimensions; flatness and parallelism 0.02 to 0.05 mm; stack TIR 0.02 to 0.05 mm |
Verification | Inter-lamination insulation resistance, segment-by-segment flux mapping, one-sided flux ratio, CMM dimensional report, bond shear testing, salt spray and media-resistance data |
Linear motor magnet tracks. Lithography stages, wafer and reticle positioning, flat-panel inspection, precision CNC and maglev transport, where high relative velocity between track and coils makes lamination essential and the Halbach sequence puts the field where the coils are.
High-speed servo motors and spindles. Machine tools, pick-and-place heads and semiconductor handling equipment running well above 20,000 rpm, where a sinusoidal field and low magnet self-heating raise continuous torque density.
Electric vehicle traction and in-wheel motors. Axial-flux and high-speed radial-flux machines in which removing the back-iron cuts mass while lamination protects the magnet against inverter harmonics and sustained high-speed duty.
Robot joint motors and collaborative actuators. Low cogging torque for smooth low-speed motion, low rotating inertia, and a quiet back face that keeps stray field away from joint encoders and sensors.
Magnetic gears, high-speed couplings, bearings and flywheels. Topologies in which the magnets see very high-frequency internal fields and solid magnets would simply run too hot to hold rated performance.
Scientific, medical and aerospace equipment. MRI and magnetic-refrigeration assemblies, particle and mass-spectrometer instruments, UAV propulsion and aircraft actuators, where thermal margin, low stray field and traceable inspection all matter at once.
FAIZEAL is a magnet engineering and manufacturing company, not a trading company. Precision slicing, insulation coating, fixture and magnetising-tool design, bonding, grinding and flux verification are carried out in-house, and Halbach arrays, laminated magnets and magnetic couplings are core products rather than sidelines.
On a part like this the lamination, the glue line and the magnetisation angle are one coupled system, and they have to be engineered by the team that builds them.
We have supplied custom magnetic assemblies to robotics, new-energy and industrial customers in more than 30 countries since 2017. Finite-element-based magnetic and structural assessment is part of the design review, not a paid extra, and small-batch multi-variety production is normal for us because custom arrays are what we build.
We also say when this architecture is the wrong answer. At low electrical frequency and modest speed, a solid magnet with back-iron is usually cheaper. If one-sided flux is not needed, a conventional multi-pole array is simpler. The recommendation follows the machine, not the process we happen to prefer.
Send us the pole pitch and pole count, the working electrical frequency and speed, the air gap, the target working-side flux density, the allowable back-side stray field, the space envelope and temperature range, and any coating or bonding requirements.
Our engineers will return a segment allocation, a lamination thickness and insulation system, magnetic and structural simulation results, a bonding and inspection plan, and a quotation.
Prototypes are available with fast sample turnaround, and production scales on the same tooling, magnetising head and inspection plan.
Give us the field you need. We will build the stack that delivers it. |
FAIZEAL · fzmag.com · Custom laminated Halbach array magnets and magnetic assemblies · sales@fzmag.com
Right-angle transmission, parallel transmission, wall-climbing robot
Right-angle transmission, parallel transmission, wall-climbing robot